Facade 34P Hidden Vent

Introduction

The 34P offers enhanced architectural performance. Flush sash-to-frame design utilizes state of the art manufacturing techniques to deliver performance, configurations, flexibility, competitive cost and reduced lead trims.

  • Frame: 3-1/4” depth
  • Sash 3-1/4" depth
  • Tubular sash and meeting rails
  • Deep water leg sill
  • Sealing return and equal/unequal frame legs
  • Flush sash to frame
  • Extruded screw spline joinery
  • Pour-Debridge thermal break
  • Sash is corner-keyed, sealed and hydraulically staked
  • Replaceable, high quality compression seals
  • Stainless steel four-bar hinges
  • High quality cam and multi-point locks
  • In-house anodized and organic finishes
  • Air Infiltration: <.10 CFM/sq.ft. (6.24 PSF) per ASTM E283
  • Static Water: 12 PSF per ASTM E331
  • Deflection Load: +/-65 PSF per ASTM E330
  • Structural Load +/- 97.5 PSF per ASTM E330
    CAD DetailsClick to expand [+] / collapse [–]. Click link on right to download file.

    Facade 34P Hidden Vent: Accessories facade_34p_hidden_vent_accessories_cad.pdf facade_34p_hidden_vent_accessories_dwg.zip

    • Bead Options (DWG)
      Blind Options (1 of 3) (DWG)
      Blind Options (2 of 3) (DWG)
      Blind Options (3 of 3) (DWG)
      Mullion Options (1 of 2) (DWG)
      Mullion Options (2 of 2) (DWG)
      Panning Options (1 of 6) (DWG)
      Panning Options (2 of 6) (DWG)
      Panning Options (3 of 6) (DWG)
      Panning Options (4 of 6) (DWG)
      Panning Options (5 of 6) (DWG)
      Panning Options (6 of 6) (DWG)
      Receptor Options (1 of 2) (DWG)
      Receptor Options (2 of 2) (DWG)
      Screens - Blind Control - Outward Projected Outswinging Casement - OPOC (1 of 2) (DWG)
      Screens - Blind Control - Outward Projected Outswinging Casement - OPOC (2 of 2) (DWG)
      Screens - Flat - Inward Projected - Inswinging Casement - IPIC (DWG)
      Screens - Flat - Inside Removable - Inward Projected Inswinging Casement - IR-IPIC (DWG)
      Screens - Flat - Outward Projected - Outswinging Casement - OPOC (DWG)
      Screens - Wicket - EL - OPOC (1 of 3) (DWG)
      Screens - Wicket - EL - OPOC (2 of 3) (DWG)
      Screens - Wicket - EL - OPOC (3 of 3) (DWG)
      Slab Cover Options (1 of 3) (DWG)
      Slab Cover Options (2 of 3) (DWG)
      Slab Cover Options (3 of 3) (DWG)
      Snap Trim Options (1 of 3) (DWG)
      Snap Trim Options (2 of 3) (DWG)
      Snap Trim Options (3 of 3) (DWG)
      Trim Miscellaneous Alcoa Sills (1 of 2) (DWG)
      Trim Miscellaneous Alcoa Sills (2 of 2) (DWG)
      Trim Miscellaneous Sealant Backers (DWG)
      Trim Miscellaneous Sealant Backers 3 1/4" Systems (DWG)
      Trim Miscellaneous Stools (1 of 4) (DWG)
      Trim Miscellaneous Stools (2 of 4) (DWG)
      Trim Miscellaneous Stools (3 of 4) (DWG)
      Trim Miscellaneous Stools (4 of 4) (DWG)

    Facade 34P Hidden Vent: FX004 facade_34p_hidden_vent_fx004_cad.pdf facade_34p_hidden_vent_fx004_dwg.zip

    • Fixed over Fixed - FX004 (DWG)

    Facade 34P Hidden Vent: FXFXIC facade_34p_hidden_vent_fxfxic_cad.pdf facade_34p_hidden_vent_fxfxic_dwg.zip

    • Fixed by Fixed by Inswinging Casement - FXFXIC (1 of 3) (DWG)
      Fixed by Fixed by Inswinging Casement - FXFXIC (2 of 3) (DWG)
      Fixed by Fixed by Inswinging Casement - FXFXIC (3 of 3) (DWG)

    Facade 34P Hidden Vent: IC001 facade_34p_hidden_vent_ic001_cad.pdf facade_34p_hidden_vent_ic001_dwg.zip

    • Inswinging Casement - IC001 (DWG)

    Facade 34P Hidden Vent: IC002 facade_34p_hidden_vent_ic002_cad.pdf facade_34p_hidden_vent_ic002_dwg.zip

    • Inswinging Casement by Inswinging Casement - IC002 (1 of 2) (DWG)
      Inswinging Casement by Inswinging Casement - IC002 (2 of 2) (DWG)

    Facade 34P Hidden Vent: IC004 facade_34p_hidden_vent_ic004_cad.pdf facade_34p_hidden_vent_ic004_dwg.zip

    • Fixed by Inswinging Casement - ICR004 (1 of 3) (DWG)
      Fixed by Inswinging Casement - ICR004 (2 of 3) (DWG)
      Fixed by Inswinging Casement - ICR004 (3 of 3) (DWG)

    Facade 34P Hidden Vent: ICIC facade_34p_hidden_vent_icic_cad.pdf facade_34p_hidden_vent_icic_dwg.zip

    • Inswinging Casement by Inswinging Casement - ICIC (1 of 2) (DWG)
      Inswinging Casement by Inswinging Casement - ICIC (2 of 2) (DWG)

    Facade 34P Hidden Vent: IP001 facade_34p_hidden_vent_ip001_cad.pdf facade_34p_hidden_vent_ip001_dwg.zip

    • Inward Projected - IP001 (DWG)

    Facade 34P Hidden Vent: IP006 facade_34p_hidden_vent_ip006_cad.pdf facade_34p_hidden_vent_ip006_dwg.zip

    • Inward Projected Over Inward Projected - IP006 - (1 of 2) (DWG)
      Inward Projected Over Inward Projected - IP006 (2 of 2) (DWG)

    Facade 34P Hidden Vent: IP007 facade_34p_hidden_vent_ip007_cad.pdf facade_34p_hidden_vent_ip007_dwg.zip

    • Fixed over Inward Projected (1 of 2) (DWG)
      Fixed over Inward Projected (2 of 2) (DWG)

    Facade 34P Hidden Vent: IPIP facade_34p_hidden_vent_ipip_cad.pdf facade_34p_hidden_vent_ipip_dwg.zip

    • Inward Projected by Inward Projected (1 of 2) - IPIP (DWG)
      Inward Projected by Inward Projected (2 of 2) - IPIP (DWG)
    Specifications

    Facade 34P Hidden Vent Specifications Master Guide Specifications Facade 34P- 2014.docx

    Literature

    • Facade 34P Hidden Vent Product Data(PDF)