Facade 37E Hidden Vent

Introduction

The 37E utilizes Polyamide thermal break technology allowing for dual color and finish combinations. Flush sash-to-frame design utilizes state of the art manufacturing techniques to deliver performance, configurations, flexibility, competitive cost and reduced lead trims.

  • Frame: 4” depth
  • Sash 4" depth
  • Tubular sash and meeting rails
  • Deep water leg sill
  • Sealing return and equal/unequal frame legs
  • Flush sash to frame
  • Extruded screw spline joinery
  • Polyamide thermal break
  • Sash is corner-keyed, sealed and hydraulically staked
  • Replaceable, high quality compression seals
  • Stainless steel four-bar hinges
  • High quality cam and multi-point locks
  • In-house anodized and organic finishes
  • Air Infiltration: <.10 CFM/sq.ft. (6.24 PSF) per ASTM E283
  • Static Water: 12 PSF per ASTM E331
  • Deflection Load: +/-65 PSF per ASTM E330
  • Structural Load +/- 97.5 PSF per ASTM E330
    CAD DetailsClick to expand [+] / collapse [–]. Click link on right to download file.

    Facade 37E Hidden Vent: Accessories facade_37e_hidden_vent_accessories_cad.pdf facade_37e_hidden_vent_accessories_dwg.zip

    • Mullion Options (1 of 1) (DWG)
      Panning Options (1 of 6) (DWG)
      Panning Options (2 of 6) (DWG)
      Panning Options (3 of 6) (DWG)
      Panning Options (4 of 6) (DWG)
      Panning Options (5 of 6) (DWG)
      Panning Options (6 of 6) (DWG)
      Receptor Options (1 of 3) (DWG)
      Receptor Options (2 of 3) (DWG)
      Receptor Options (3 of 3) (DWG)
      Screens - Flat - Inward Projected - Inswinging Casement - IPIC (DWG)
      Screens - Flat - Inside Removable - Inward Projected - Inswinging Casement - IR - IPIC (DWG)
      Slab Cover Options (1 of 3) (DWG)
      Slab Cover Options (2 of 3) (DWG)
      Slab Cover Options (3 of 3) (DWG)
      Snap Trim Options (1 of 3) (DWG)
      Snap Trim Options (2 of 3) (DWG)
      Snap Trim Options (3 of 3) (DWG)
      Trim Miscellaneous Alcoa Sills (1 of 2) (DWG)
      Trim Miscellaneous Alcoa Sills (2 of 2) (DWG)
      Trim Miscellaneous Stools (1 of 4) (DWG)
      Trim Miscellaneous Stools (2 of 4) (DWG)
      Trim Miscellaneous Stools (3 of 4) (DWG)
      Trim Miscellaneous Stools (4 of 4) (DWG)

    Facade 37E Hidden Vent: FX004 facade_37e_hidden_vent_fx004_cad.pdf facade_37e_hidden_vent_fx004_dwg.zip

    • Fixed over Fixed - FX004 (1 of 2) (DWG)
      Fixed over Fixed - FX004 (2 of 2) (DWG)

    Facade 37E Hidden Vent: FXFXIC facade_37e_hidden_vent_fxfxic_cad.pdf facade_37e_hidden_vent_fxfxic_dwg.zip

    • Fixed by Fixed by Inswinging Casement - FXFXIC (1 of 3) (DWG)
      Fixed by Fixed by Inswinging Casement - FXFXIC (2 of 3) (DWG)
      Fixed by Fixed by Inswinging Casement - FXFXIC (3 of 3) (DWG)

    Facade 37E Hidden Vent: IC001 facade_37e_hidden_vent_ic001_cad.pdf facade_37e_hidden_vent_ic001_dwg.zip

    • Inswinging Casement - IC001 (DWG)

    Facade 37E Hidden Vent: IC007 facade_37e_hidden_vent_ic007_cad.pdf facade_37e_hidden_vent_ic007_dwg.zip

    • Fixed over Inswinging Casement - ICR007 (1 of 2) (DWG)
      Fixed over Inswinging Casement - ICR007 (1 of 2) (DWG)

    Facade 37E Hidden Vent: ICIC facade_37e_hidden_vent_icic_cad.pdf facade_37e_hidden_vent_icic_dwg.zip

    • Inswinging Casement by Inswinging Casement - ICIC (1 of 2) (DWG)
      Inswinging Casement by Inswinging Casement - ICIC (2 of 2) (DWG)
    Specifications

    Facade 37E Hidden Vent Specifications Master Guide Specifications Facade 37E- 2014.docx

    Literature

    • Facade 37E Hidden Vent Product Data(PDF)